Hike.uno
Hike.uno
Login
Login
Username:
Password:
Login
Not registered yet? Registration.
Forgot password?
News / Recall of Climbing Kits - Mammut

Recall of Climbing Kits - Mammut

24.11.2025
Mammut has issued a precautionary recall of Skywalker Pro Via Ferrata and Skywalker Pro Turn Via Ferrata climbing kits due to a possible failure in the locking mechanism of the karabiners, which could endanger user safety.
Mammut, as part of routine quality control, discovered a potential defect in the locking mechanism of the karabiners in via ferrata climbing kits. The issue occurs primarily at low temperatures, when the plastic locking levers can bend or stiffen, preventing proper closure of the karabiner.
The recall affects the following models equipped with Skywalker Pro karabiners:
Model – Description
2040-02840 Skywalker Pro Via Ferrata kit
2040-02850 Skywalker Pro Turn Via Ferrata kit
2040-02870 Skywalker Pro Via Ferrata package (including helmet and harness)
If you purchased the package with helmet and harness, check only the via ferrata kit — other products are not affected mammut.dani-o.com.
How to check your equipment?
Look for the serial number on the karabiner or energy absorber label.
If the number is 07/2021 or 11/2022 (without the letter “R”), return the product immediately — no check needed.
For all other batches:
Place the kit in the refrigerator (0–10 °C) for at least 1 hour.
Then open and close the karabiner several times.
If it gets stuck in the open position or moves with difficulty, it is defective.
What to do if the karabiner is defective?
Mammut urges all users to return defective products for replacement or refund. Details on the return procedure are available on the official Mammut U.S. Consumer Product Safety Commission page.
Karabiners are critical safety elements in via ferrata climbing. Their reliability must be flawless, as failure means direct risk of fall. Mammut has shown responsibility and proactivity with this recall, but also warned that even top equipment is not immune to defects.

Dynamic rope SUNRISE 9.2 mm 50 m – is subject to a safety recall regarding the listed rope batches.
Stop using them and contact BEAL customer service for free replacement.
This recall affects the following serial numbers found on the rope label and packaging:
004A01235824
005A01235824
006A01235824
007A01235824
009A01235824
012A01235824
014A01235824

Source: https://gore-ljudje.net/informacije/obvestila-48-25/
         